To warm the ground to suppress the important part of warm acceptance

Floor heating to suppress the important part of acceptance of warmth

Warm pressure test should pay attention to observe the change of the pressure gauge number. If the number of the pressure gauge does not change, it means that the floor heating pipeline is in good condition; if the pressure gauge's number declines slowly, it shows that the floor heating pipeline is likely to have a drip; if the pressure is not at all , indicating that the valve is not closed, that is, there is a problem with the floor heating pipe.

Install a floor heating system to select a professional floor heating company. A professional floor heating company can selectively select various insulation materials and control systems according to the structure, orientation, and layout of the user's room to effectively reduce various problems that occur after the floor heating is suppressed. In addition, the floor heating pipes need to be cleaned after 3-5 years of use. This is not an ordinary family and it requires a professional heating company to construct.

Warm pressure

Hand to teach you how to warmly suppress.

1. Slow water injection through the water separator, while the air in the pipe is discharged.

2. After being filled with water, check for watertightness.

3. Use a manual pump to slowly raise the pressure.

4. After boosting to the specified test force, stop the pressure and adjust the pressure for 1 hour to observe whether there is any water leakage.

5. After one hour of voltage stabilization, the pressure is compensated to the specified test pressure value. The pressure drop within 15 minutes does not exceed 0.05 Mpa without leakage. The floor heating system has not been debugged and is prohibited from operating.

6. Prior to the warm-up pressure test, safe and effective fixation and protection measures shall be taken for the pressure test piping and components.

7. The test pressure should not be less than the system static pressure plus 0.3Mpa, but not more than 0.6Mpa.

8. In the winter warmth pressure test, reliable antifreeze measures should be taken.

Renovation company room

Solar Billboard Spot Light

1. Solar panel : 4.5W 9W 18W 17% efficiency More than 10 years lifespan
2. LED : White LEDs 24pcs 48pcs 60pcs/More
3. Charging Method : Solar power
4, Charging time :7-8hrs
5.Lighting time: 2-3 days once full charged 5 hrs 100% bright there after 25% Dim till dawn
6.Battery : 18650 li-ion battery 3.7V 4400mAh/8800mah/17600mah
7. Material : Aluminum Alloy+ABS IP level : IP65

9. With Light sensor Working Temperature: -25℃ to 65℃

10.Very suitable using in Double side real estate signboard, Garden,Park,Pathway, courtyard, street,roadway, sidewalk, farm & ranch etc ,

Signboard , billboard lighting , and door number plate .


Solar Billboard Light,Aluminum Solar Billboard Light,Double Color Solar Billboard Lamp.solar billboard spot light

Shenzhen You&My Electronic Technology Co., Ltd , https://www.ymledtrade.com