one. Do not vibrate after the power is turned on. Check whether the fuse of the electric controller is dissolved, whether the electrical components are loose, and whether the plug and socket are in poor contact. If the conveying speed does not meet the requirements, pay attention to the following three points;
1. Check if the screws that fasten the elastic element are loose
2. Whether the spring piece breaks
3. Whether the electromagnetic gap is too large, the normal gap corresponds to the distance between the electromagnet of the small vibration plate and the armature in the range of 0.5MM to 1.2MM. The iron core and the armature working face are not parallel to each other not more than 0.02MM
two. The electromagnet coil has a high temperature or burns the coil with 2 points:
1. The distance between the electromagnetic and the armature is too large, and the coil is easy to burn.
2. Electromagnets adapted to full-wave vibrations may experience high temperatures if used in half-wave power supplies
Concerned about surprises
Label: vibrating disk common faults and troubleshooting methods